A highly sensitive LC-MS/MS method for the trace level determination of genotoxic impurities, Cinnamyl chloride and Benzhydryl chloride, in Cinnarizine drug substance was developed and validated. Chromatographic separation was successfully achieved on Atlantis d C18 column with dimensions 150× 4.6mm and particle size: 5µm. 0.1% Trifluoroacetic acid in water and 100% acetonitrile was used as mobile phases with gradient mode of elution at 1.0mL/min flow rate. Mass spectroscopic detection was carried out with selective ion monitoring (SIM) technique in positive mode at m/z 117 and 167 for Cinnamyl chloride and Benzhydryl chloride respectively. Developed method was proven to be selective, sensitive, and precise for the quantification of potential genotoxic impurities in Cinnarizine by validating as per the regulatory guidelines. The LOD and LOQ values observed for Cinnamyl chloride were 0.49 and 1.47ppm and for Benzhydryl chloride 0.55 and 1.67ppm respectively. Precision of the method at LOQ level was shown with good % RSD of 4.21. Method was proven linear from LOQ to 150% level with a correlation of 0.996 and accurate with a range of recovery from 86.4 to 100.8%. This highly sensitive method can be used to control both the genotoxic impurities in Cinnarizine drug substance by LC-MS/MS.